Air feeder troubleshooting
Select a part or a fault. Every number is the part number in the manual.
Before you touch the feeder: stop the press, isolate the press, the feeder and the air supply, and release the stored air pressure. Never reach into the clamps while they can move. Tests and repairs are for qualified people only.
Every fault, by symptom.
Select a fault. The page goes back to the model and marks the parts to look at.
Will not start or does not feed
Not enough lubricating oil
- Parts
- Air filter unit, upstream of the inlet
- Check
- Look at the oil level in the oiler of the air filter unit. With the feeder running, oil mist should show at the exhaust ports on both sides.
- Fix
- Add lubricating oil. If the unit passes no oil, clean or replace the air filter unit.
- Replace
- Air filter unit (filter, regulator and oiler), if it passes no oil.
Air pressure too high or too low
- Parts
- Air filter unit, upstream of the inlet
- Check
- Read the gauge on the regulator.
- Fix
- The regulator should read 4.5 kg/cm² with the compressor supplying at least 5 kg/cm². Adjust the compressor if it does not.
Air hose or quick coupling worn
- Parts
- Check
- Look along the air hose and at the quick coupling on the air inlet.
- Fix
- Replace the worn hose or coupling with a new part.
- Replace
- Air hose or quick coupling.
The trigger signal or the air does not reach the feeder
- Parts
- Check
- Standard and R types: watch whether the striker presses the trigger rod down and lets it go on every stroke. E and E+R types: check the cam, the limit switch, the 24 V supply and the solenoid valve; a brief press on the manual override button of the valve gives an unloaded check. On every type, check that the air valve at the inlet is open.
- Fix
- Put right the supply or trigger fault you have confirmed first. Open the valve or the cylinder only when the fault is narrowed down to it.
The moving clamp is blocked
- Parts
- Check
- Isolate the air and the press. Look along the guide rods and the path of the moving clamp for anything in the way.
- Fix
- Clear the obstruction. Do not force the moving clamp.
The feeder was stopped for a long time
- Parts
- Fix
- Before start-up, push the moving clamp toward the main body by hand. If it still will not start, clean the feeder, replace the seal rings and service it. Next time, lower the trigger rod before you switch off.
- Replace
- Seal rings, if it still will not start after cleaning.
Directional valve dry and stuckSeal point 1 of 4
- Parts
- Check
- Open the cover of the directional valve. Is it dry inside? Hook the valve housing out with circlip pliers and look for dirt. Shake the valve: if the white seal element inside it moves, it is good; if it does not, it is stuck.
- Fix
- Hold a hand over the valve and blow air into the exhaust hole with an air gun to push the white element out. Wipe the housing clean. Replace the seal ring on the element. Grease every place that has a seal ring, refit and test with air.
- Replace
- Seal ring of the directional valve.
Seal ring at the bottom of the trigger rod wornStandard and R typesSeal point 2 of 4
- Parts
- Check
- Open the trigger rod assembly and hook out the bottom part with circlip pliers. Look at the ring.
- Fix
- Replace the seal ring, refit the rod and test again.
- Replace
- Seal ring at the bottom of the trigger rod.
Large seal on the feed cylinder rod wornSeal point 3 of 4
- Parts
- Check
- Remove the positioning seat and pull the rod out. The manual calls this rod the central large rod.
- Fix
- Replace the seal, grease it, refit the rod and test with air.
- Replace
- Large seal of the feed cylinder rod.
Bottom seals of the fixed clamp pistons wornSeal point 4 of 4
- Parts
- Check
- Take out the fixed clamp pistons on both sides of the main body.
- Fix
- Each piston has two seals: replace the one at the bottom. Refit the spring and the pressure plate, then test with air.
- Replace
- Bottom seal of each fixed clamp piston.
Chips or dirt inside the cylinder
- Parts
- Fix
- Take the feeder apart and clean it.
Feed length is short or uneven, or the strip slips
Speed set too high
- Parts
- Check
- Is the press running faster than the feeder can follow?
- Fix
- Turn the speed control screw clockwise.
Feed length not set correctly, or the setting has come loose
- Parts
- Check
- Measure the feed length as described under Adjust. Check that the feed length screw has not moved, and how any spacers are arranged.
- Fix
- Reset the feed length screw, then the speed control screw.
Air pressure too high, too low or unstable
- Parts
- Air filter unit, upstream of the inlet
- Check
- Check whether the pressure gauge is damaged. The regulator should read 4.5 kg/cm² with the compressor supplying at least 5 kg/cm².
- Fix
- Adjust the compressor. The clamps grip with the supply pressure, so the wrong pressure also means the wrong clamp force.
Restart after more than 12 hours stopped
- Parts
- The whole feeder
- Fix
- Run the feeder empty, without material, for 3 to 5 minutes, then feed. The colder the weather, the longer the idle run.
Trigger rod not pressed deep enoughStandard and R types
- Parts
- Check
- The moving clamp touches only the nylon washer, not the feed length screw.
- Fix
- Lower the striker screw on the press slide, slowly.
Trigger rod pressed too deepStandard and R types
- Parts
- Check
- The moving clamp touches only the feed length screw, not the nylon washer.
- Fix
- Raise the striker screw, slowly. A rod that is pressed too deep can bend or break.
Moving clamp speed set too slow
- Parts
- Check
- The moving clamp stops short of both ends, with equal gaps on both sides.
- Fix
- Turn the speed control screw counterclockwise until the moving clamp touches both ends.
Double feed or missed feed
- Parts
- Check
- Check where the striker hits, whether the trigger rod comes back up, how the valve responds, and the timing against the press cycle.
The trigger rod is not held down for long enoughStandard and R types
- Parts
- Check
- This shows on a long feed, a short press stroke or a fast press: the feed cannot keep up.
- Fix
- Fit a spring on the striker screw (a spring-loaded striker) so the rod stays pressed for longer. Or change to the E type, where a solenoid valve replaces the trigger rod.
Short feed only at production speed
- Parts
- Air supply and the press line
- Check
- Test at production speed, not only in a slow manual cycle. The usual causes are too little feed time, unstable air, pull from upstream, guide friction or clamp slip.
Clamp plate worn smooth
- Parts
- Check
- Remove the clamp plate and look at its face. After years of use the face can be polished smooth, and the material slips.
- Fix
- Surface-grind the whole face of the plate flat, which is the manual's remedy, then check the feed. Or fit a matched replacement plate. Do not raise the pressure to hide a worn plate.
- Replace
- Clamp plate, if grinding does not bring the grip back.
Seals of the moving clamp pistons worn
- Parts
- Check
- Test with air and watch the moving clamp plate. Does it respond slowly?
- Fix
- Replace the seals of the pistons on both sides. Grease the seals, put the spring in place, refit the plate and test with air.
- Replace
- Seals of the moving clamp pistons, both sides.
Oil or dirt on the gripping faces or on the material
- Parts
- Check
- Look at the clamp faces and at the surface of the strip.
- Fix
- Clean the contact parts.
Air pressure drops during the stroke
- Parts
- Check
- Check the regulator, the size of the air line and the cylinder seals.
The fixed clamp is not holding
- Parts
- Check
- The strip moves backward while the moving clamp returns. Look at the fixed clamp plate and its pistons.
- Fix
- Replace gripping parts you have confirmed are worn with matched parts.
- Replace
- Worn fixed clamp plate or piston seals, matched to your model.
Strip too thin
- Parts
- Fix
- Fit guide blocks on the main body. Or change from pushing to pulling: mount the feeder after the die.
Strip drifts or warps; feeder not in line with the die
- Parts
- Check
- Check the height of the feeder against the die entry, and the flatness of the strip.
- Fix
- Keep the feeder level and in line with the die, horizontally and vertically.
Strip walks sideways
- Parts
- Check
- Check the centre line, the position of the width guide wheels, the alignment upstream and the die entry.
- Fix
- Correct the line. Tighter guides cannot make up for a line that is out of alignment.
The feeder pulls against the coil or a tight loop
- Parts
- Check
- Look at the loop between the decoiler and the feeder. Check for drag at the guides and at the die entry.
- Fix
- Give the feeder prepared strip: the decoiler must keep a free loop in front of it. An air feeder should not pull straight from the coil.
Guide rods worn, or the mounting moves
- Parts
- Check
- Look at the guide rods for wear. Check that the feeder does not move on its mounting.
- Replace
- Guide rods: ask us for matched parts.
Error in the die itself
- Parts
- The die
- Fix
- Calibrate the die.
The die has no pilot pins
- Parts
- The die
- Fix
- Correct the die. With pilot pins in the die, an R type feeder lets them pull the strip into position.
The fixed clamp still holds the strip as the pilot pins enterR and E+R types
- Parts
- Check
- Pilot holes are stretched or marked, or the pitch varies on a die with pilot pins. On an R type, check the release timing against the moment the pilots enter.
- Fix
- Use the R type pilot release. Set it so the switch acts as the tip of the pilot pin enters the hole. Example only: on at 160°, off at 180° to 190°.
Release too early or too longR and E+R types
- Parts
- Check
- The strip floats or moves before the pilot pins correct it. Check the R timing.
- Fix
- Shorten the release or retime it.
Material breaks during drawing: the fixed clamp holds while the die draws the stripR and E+R types
- Parts
- Fix
- The R valve relaxes the fixed clamp plate at that moment.
The moving clamp does not return
Return signal missing
- Parts
- Check
- Standard and R types: the moving clamp returns while the trigger rod is held down, so check that the striker presses it. E and E+R types: the feeder returns while the coil is on, so check the cam, the limit switch and the 24 V supply.
- Fix
- Correct the control fault you find.
Directional valve not switching
- Parts
- Check
- Open the cover of the directional valve. Is it dry inside? Shake the valve: if the white seal element inside it does not move, it is stuck.
- Fix
- Free and clean the valve, replace the seal ring on the element, grease it, refit and test with air.
- Replace
- Seal ring of the directional valve.
Exhaust restricted
- Parts
- Check
- Check that the exhaust ports are open and that nothing has been fitted into them.
- Fix
- Service the restricted part. Never block an exhaust port.
Mechanical resistance on the guide path
- Parts
- Check
- Isolate the air and the press, then inspect the guide rods and the path of the moving clamp.
- Fix
- Remove the obstruction.
Cushion action is too slowModels with a buffer
- Parts
- Buffer
- Check
- The cushion setting or its flow path restricts the return. Check the cushion adjustment, the exhaust path and how the cylinder responds.
Air leaks
Leak at an exhaust port
- Parts
- Check
- Find which exhaust port leaks. On standard and R types, look at the trigger rod: is it bent?
- Fix
- Replace the worn seal ring or control tube, or the bent trigger rod and its valve, with new parts.
- Replace
- Worn seal ring or control tube; a bent trigger rod and its valve.
Leak at the air inlet joint
- Parts
- Check
- Turn the air on and find the leak. A threaded fitting is usually the cause.
- Fix
- Take out the leaking fitting, wrap new thread seal tape on it, refit it and test with air.
Leak at a tube, coupling or fitting
- Parts
- Check
- Check the tightness of the fittings, the tube and the quick coupling at the inlet.
- Fix
- Isolate and release the pressure. Replace or reseal only the connection you have confirmed is leaking, with compatible parts.
- Replace
- The leaking tube, coupling or fitting.
Leak at a valve or cylinder
- Parts
- Check
- Note the valve position and whether the leak is continuous, only during feed, or only during return. Some exhaust air is normal while the valve works.
- Fix
- Replace the seal you have confirmed is worn. The seal positions are listed under Wear parts.
- Replace
- The seal you have confirmed is worn.
Seals swollen and damaged by lack of oil
- Parts
- Air filter unit, upstream of the inlet
- Check
- Oil mist should show at the exhaust ports on both sides.
- Fix
- Keep the oiler filled to eight-tenths with 68-grade circulating oil.
Leak after fitting an E type plug or valve insertE and E+R types
- Parts
- Check
- The insert was forced in, or a seal was cut, twisted, pinched or dry. Look at the rubber seal and the O-rings for cuts, flat spots or dryness.
- Fix
- Replace a damaged seal: do not reuse it. Put a light film of pneumatic lubricant on it and press the assembly in straight.
- Replace
- Any damaged seal or O-ring of the insert.
Slow, jerky or sticking motion
Not enough air volume, or the pressure falls during the cycle
- Parts
- Air filter unit, upstream of the inlet
- Check
- Compare the air supply while the line is running with what the feeder needs. Where an air tank is fitted, check its capacity.
- Fix
- Restore the air supply and the air preparation, then test again.
Water or oil in the compressed air
- Parts
- Air filter unit, upstream of the inlet
- Check
- Look at the filter.
- Fix
- Keep the compressed air clean and stable. Clean the filter mesh and drain the moisture.
Poor lubrication
- Parts
- Air filter unit, upstream of the inlet
- Check
- Check the oil level in the oiler and the oil mist at the exhaust ports.
- Fix
- Restore the lubrication, then test again.
Guide rods dirty or worn
- Parts
- Check
- Inspect the guide rods and the contact points for dirt or wear.
- Fix
- Clean them. Replace parts you have confirmed are worn.
- Replace
- Guide rods, if they are worn.
Speed has dropped little by little
- Parts
- Check
- Check the setting of the speed control screw: see Adjust.
- Fix
- Reset the speed. Do not turn every speed screw to hide binding.
The moving clamp plate responds slowly
- Parts
- Check
- The seals of the moving clamp pistons are worn. Test with air and watch the clamp.
- Fix
- Replace the seals of the pistons on both sides and grease them.
- Replace
- Seals of the moving clamp pistons, both sides.
Hard impact at the end of the strokeModels with a buffer
- Parts
- Buffer
- Check
- The buffer stroke is too short. It should be no more than 50% of the compression travel of the shock absorber.
- Fix
- Increase the buffer stroke a little at a time until the damping works.
Marks on the strip
Dirt on the rollers or on the clamp faces
- Parts
- Check
- Inspect the guide rollers and both clamp faces. Compare the strip going in with the strip coming out to see where the marks first appear.
- Fix
- Clean them.
Damaged contact surfaces
- Parts
- Check
- Inspect the guide rollers and both clamp faces for damage.
- Fix
- Replace the damaged contact part with one matched to your model. If a clamp face is reground or the grip is reduced, check the feed afterwards.
- Replace
- The damaged roller or clamp plate, matched to your model.
Strip out of line
- Parts
- Check
- Check the alignment of the strip through the feeder.
- Fix
- Correct the alignment.
Thin strip is marked, buckled or slips
- Parts
- Check
- Inspect both faces of the strip after many cycles, not after one manual index.
- Fix
- Start from the lowest stable pressure that completes the feed without slip. Set the side guides for the real variation of the edge and the burr.
Trigger rod bent or broken
The striker pressed the trigger rod too lowStandard and R types
- Parts
- Check
- Raise the striker screw. Inch the press slide down to bottom dead centre and watch the rod.
- Fix
- With the air off and the slide at bottom dead centre, set the striker so that the rod is pressed down but not pushed too deep. Replace a bent rod: it also leaks air at the exhaust.
- Replace
- Trigger rod.
No fault in the list for this choice.
All 73 parts, by assembly.
Select a part to find it on the exploded view and to ask for it. The numbers are the part numbers of the manual, not order codes.
Not in the manual parts list: the E type solenoid valve and the R type release valve. Both are on the E+R 3D model.
Set the feed length, the speed and the timing.
Adjust without material first, then check with strip. The valve angles are the manual's examples, not settings.
Feed length
- Close the air valve at the inlet. Turn the speed control screw counterclockwise one to two turns, so that the moving clamp can be moved by hand.
- Press the moving clamp against the feed length screw. Measure the distance between the nylon washer and the moving clamp with a vernier caliper or a gauge block. That distance is the feed length.
- Turn the feed length screw: clockwise is shorter, counterclockwise is longer.
- Push the moving clamp to the nylon washer and back to the screw three times, then measure again.
- For a large change, use the stepped locking bar first, then the screw for the fine setting.
- Check with strip: mark a reference, cycle several feeds, measure the total distance and divide by the number of feeds. An empty test proves movement only.
Speed
- Speed control screw: clockwise is slower, counterclockwise brings it back to normal speed.
- In continuous stamping, the feeder should run slightly faster than the press.
- A speed set too high is the first cause the manual lists for inaccurate feeding: turn the screw clockwise.
- There is no separate adjustment for clamp pressure in the manual. The only pressure setting is the regulator: 4.5 kg/cm².
Timing of the trigger rod Standard and R types
- Work without material. Raise the striker screw on the press slide first.
- Inch the slide slowly down to bottom dead centre. Make sure the striker does not press the trigger rod too low: the rod can bend or break.
- With the air off and the slide at bottom dead centre, set the striker so that the rod is pressed down but not pushed too deep.
- Turn the speed control screw clockwise so the moving clamp runs a little slower, start the press, and watch whether the moving clamp touches both the nylon washer and the feed length screw.
- Touches only the nylon washer: lower the striker slowly. Touches only the feed length screw: raise it slowly. Stops short of both, with equal gaps: turn the speed control screw counterclockwise until it touches both ends.
- To shorten the feed at the same press speed: raise the striker first, then turn the speed control screw clockwise. To lengthen it: lower the striker first, then turn the screw counterclockwise.
- Long feed, short press stroke or a fast press: fit a spring-loaded striker so the rod stays pressed for longer, or use the E type.
Timing of the E valve E and E+R types
- Coil on: the feeder returns. Coil off: it feeds.
- Change the cam angle before you start the machine. Turn the press slowly by hand until the cam touches the limit switch.
- Start without material and measure the feed length first. The switch must act once at the intended point and reset on every cycle.
- Example, not a setting: on at 90°, off at 270°, with 0° at top dead centre. Move the cam to suit your press.
Timing of the R valve R and E+R types
- Set the cam, or the guide rod on the slide, so that the limit switch acts at the moment the tip of the pilot pin enters the pre-punched hole.
- The contact travel between the cam or guide rod and the switch must be more than one quarter of the press stroke.
- Release only for as long as needed, then confirm that the fixed clamp grips again before the next feed.
- Too late: the fixed clamp still holds while the pilots correct. Too early or too long: the strip floats or moves before the pilots reach it.
- The R valve does not change the feed length, and it cannot correct a wrong pitch setting.
- Example, not a setting: on at 160°, earlier or later to suit the length of the pilot pins; off at 180° to 190°.
Buffer Models with a buffer
- The buffer stroke should be no more than 50% of the compression travel of the shock absorber.
- If the impact at the end of the stroke is too hard, increase the buffer stroke a little at a time until the damping works.
Wear parts and seals.
Most repairs are a seal ring. Select a number to see that seal on the exploded view.
| Where the seal rings are | Sign of wear | Seal ring nos. |
|---|---|---|
| 22 Directional valve, control piston and air inlet switch | Feeder stops feeding when the valve is dry and the seal sticks | , , , , , |
| 7 Trigger rod | Feeder cannot feed; air leaks at the exhaust | , |
| 38 Feed cylinder rod and buffer | Feeder cannot feed (large seal of the rod) | , , , |
| 44 Fixed clamp pistons | Feeder cannot feed (bottom seal; each piston has two) | |
| 51 Moving clamp pistons | Clamp plate responds slowly; strip slips; air leaks | , |
| Other parts that wear | Sign of wear | Remedy |
|---|---|---|
| Clamp plates, fixed and moving | The face becomes smooth and the strip slips | Surface-grind the face flat, or fit a matched new plate |
| Trigger rod | Bent; air leaks at the exhaust | Replace, then reset the striker |
| Air hose | Worn or aged; feeder is hard to start | Replace |
| Quick coupling | Worn; feeder is hard to start | Replace |
| Threaded air fittings | Leak at the joint | Wrap new thread seal tape and refit |
| Air filter unit | Poor lubrication; filter mesh clogged | Clean the mesh often; clean or replace the unit |
| Guide rods | Worn; feed becomes inaccurate | Ask us for matched parts |
Spare parts we supply
From a single valve or piston to a complete O-ring seal set for a rebuild. The manual gives no seal sizes, and a part that looks the same is not always compatible: send the model, the nameplate and the markings on the part.
Ask for a part- Directional valve
- Fixed piston
- Moving piston
- Trigger rod
- Center rod
- Small center rod
- Air intake switch
- Guide wheel
- O-ring seal set
Oil, filter and restart rules.
The manual gives no calendar. Set the intervals by how hard the feeder works.
| All the time | Oil feed from the oiler: about 1 drop every 8 to 12 feed cycles. |
|---|---|
| When you top up the oiler | Fill to eight-tenths with 68-grade circulating oil (the manual names R68 or ESSO 68). Check that oil mist shows at the exhaust ports on both sides of the feeder. |
| Often | Clean the filter mesh inside the filter. Do not use highly volatile liquids; diesel or soap powder are suitable. Drain the water from the air filter unit regularly. |
| After more than 12 hours stopped | Run the feeder empty, without material, for 3 to 5 minutes, then feed. The colder the weather, the longer the idle run. |
| Before a long stop | Lower the trigger rod before you switch off. |
| Before start-up after a long stop | Push the moving clamp toward the main body by hand first. If needed, replace the seal rings, clean and service the feeder. |
| After a die change or pitch change | Confirm the feed length. |
| After press maintenance or a valve adjustment | Check the timing. |
Quick answers.
Why is my air feeder not feeding?
Start with the air: the regulator at 4.5 kg/cm², oil in the oiler, the hoses and the quick couplings. Then check that the trigger rod is pressed and released on every stroke, or on E types that the cam, the limit switch and the solenoid valve work. If air and signal are good, the usual causes are a dry, stuck directional valve or a worn seal: at the bottom of the trigger rod, on the feed cylinder rod, or at the bottom of the fixed clamp pistons. Work through them in that order.
Why is the feed length short, or why does the strip slip?
If the moving clamp makes its full stroke but the strip moves less, the grip is slipping: look for a clamp plate worn smooth, worn seals on the moving clamp pistons, oil on the strip or low air pressure. If the moving clamp itself stops short, check the feed length screw, the speed control screw and how deep the trigger rod is pressed. Check also that the feeder is not pulling against the coil: the decoiler must keep a free loop.
Why is my air feeder leaking air?
Some exhaust air is normal while the valve works. A leak at an exhaust port usually means worn seal rings or a bent trigger rod. A leak at the air inlet joint is usually a threaded fitting that needs new seal tape. Seals that have run without oil swell and leak, so keep the oiler filled. Never plug an exhaust port to stop the sound.
Why does the moving clamp not return, or return slowly?
Check the return signal first. On standard and R types the moving clamp returns while the striker holds the trigger rod down; on E types it returns while the coil is on. Then look for a blocked exhaust port, something in the guide path, or a cushion that is set too slow.
Why is the air feeder slow or jerky at production speed?
A fault that shows only at production speed is often air supply or timing, not a broken part. Check the air volume and pressure while the line runs, water or dirt in the air, the lubrication and the guide rods. Do not raise the pressure or turn every speed screw to hide binding.
Still stuck, or need a part?
Send these six things. A person at our factory reads the message and answers it.
Both buttons open a message with the list already written in.
- Feeder model, and a photo of the nameplate
- Control type: standard, E, R or E+R
- What the feeder does, and whether at low speed or at production speed
- Strip width, thickness and feed length
- Press speed and air pressure
- A photo or a short video of the fault